Home›Repair guides›Doosan›Thermostat inspection

Doosan GE12TIC — Thermostat inspection

Maintenance · Cooling system

For the Doosan GE12TIC, from the Doosan service manual.

Browse Doosan generators & specs →

Procedure

  1. Check wax pellet and spring for damage.
  2. Put thermostat in water, heat slowly, check with thermometer.
  3. Valve starts opening at 79°C.
  4. Valve lift 8 mm or more at 94°C.
  5. Replace if defective.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Open at 79°C
  • Full open at 94°C
  • Valve lift 8 mm or more

Source: Doosan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.