Doosan GE12TIC — Initial speed controller settings
Adjustments
For the Doosan GE12TIC, from the Doosan service manual.
Browse Doosan generators & specs →
Before you start
- Be prepared for emergency shutdown to protect against runaway or overspeed
Procedure
- Set RATED SPEED potentiometer fully counterclockwise.
- Set RATED and IDLE STABILITY potentiometers to mid position.
- Set RATED and IDLE GAIN potentiometers to mid position.
- Set IDLE SPEED potentiometer fully clockwise.
- Set START FUEL LIMIT pot at mid point.
- Close circuit between terminals 9 and 10 for rated.
Specs & values
- Battery voltage at terminals 1(+) and 2(-): 18 to 32 Vdc
Source: Doosan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.