Doosan GE12TIC — Air filter element cleaning
Maintenance · Air intake system
For the Doosan GE12TIC, from the Doosan service manual.
Browse Doosan generators & specs →
Before you start
- Wear goggles when using compressed air.
Procedure
- Remove hexagon nut and dirty cartridge.
- Wipe cleaner housing with damp cloth.
- Clean by compressed air from inside (max 500 kPa).
- Or soak in lukewarm solvent 10 minutes, agitate 5 minutes, rinse.
- Dry completely before reinstalling.
- Inspect for damage; replace if damaged.
Tools required
- Compressed air gun with 90° nozzle Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Max air pressure 500 kPa
Source: Doosan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.