Home›Repair guides›Doosan›Air filter element cleaning

Doosan GE12TIC — Air filter element cleaning

Maintenance · Air intake system

For the Doosan GE12TIC, from the Doosan service manual.

Browse Doosan generators & specs →

Before you start

  • Wear goggles when using compressed air.

Procedure

  1. Remove hexagon nut and dirty cartridge.
  2. Wipe cleaner housing with damp cloth.
  3. Clean by compressed air from inside (max 500 kPa).
  4. Or soak in lukewarm solvent 10 minutes, agitate 5 minutes, rinse.
  5. Dry completely before reinstalling.
  6. Inspect for damage; replace if damaged.

Tools required

  • Compressed air gun with 90° nozzle Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Max air pressure 500 kPa

Source: Doosan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Doosan repair guides →