Doosan C185 / C185WKUB-T2 — Stopping

Operation · engine

For the Doosan C185 / C185WKUB-T2, from the Doosan owner's manual.

Applies to: Kubota 2403T engine

Before you start

  • Since the service valve is closed, air downstream of the valve may be trapped. Do not disconnect hoses until all pressure has been vented.

Procedure

  1. Close air service valves.
  2. Allow the unit to run at idle for 3 to 5 minutes to reduce the engine temperatures.
  3. Turn Power Switch to OFF position.
  4. When the engine stops, automatic blowdown valve should relieve system air pressure; if malfunction suspected, open manual blowdown valve.
  5. Never allow unit to sit under pressure when engine is not running.