Low Voltage Alternator - 4 poles — Diode Bridge Replacement
For the Low Voltage Alternator - 4 poles.
Procedure
- Remove the air ducts (3)
- Cut the fixing clamps of the exciter cables, disconnect E+, E- from the exciter
- Disconnect T1 to T6 from the terminal block (124)
- Remove the nuts on the tie rods (37)
- Remove the NDE bracket (36) using a puller: eg. U.32 - 350 (Facom)
- Unsolder the connections
- Check the bridge using an ohmmeter or a battery lamp
- Replace the bridges, respecting the polarity
- Resolder the connections
- Fit a new O ring seal in the bracket
- Refit the NDE bracket
- Connect T1 to T6 from the terminal block (124)
- Replace the fixing clamps on the cables
- Replace the air ducts (3)
Tools required
- U.32 - 350 Puller (Facom)
Source: manual:5960_en.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.