Procedure
- Turn engine until valves of cylinder No. 1 overlap.
- Adjust valve clearance on respective cylinder with feeler gauge.
- Tighten locknut in accordance with specifications. Recheck the adjustment with feeler gauge.
- Put gasket in place.
- Fit cylinder head cover. Tighten bolts in accordance with specifications.
Tools required
- Feeler gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Valve clearance inlet 0.3 mm
- Valve clearance exhaust 0.5 mm
- Valve clearance to be increased by 0.1 mm at every cylinder head gasket renewal
- Standard valve clearance to be adjusted after completion of 50 hours of operation