Home›Repair guides›Deutz›Thermostat housing repair

Deutz — Thermostat housing repair

Repair & overhaul

From a Deutz service manual covering: F2L 1011, F3L 1011, F4L 1011. Check it applies to your exact model before use.

Browse Deutz generators & specs →

Procedure

  1. Lift off cover. Remove steel gasket.
  2. Remove valve plunger housing.
  3. Take out thermostat together with spring.
  4. Remove screw plug for valve plunger (heat up screw plug).
  5. Remove valve plunger together with compression spring.
  6. Inspect individual component parts.
  7. Refit valve plunger together with compression spring. Watch bypass bore.
  8. Spread thread of screw plug with sealing compound Loctite 648.
  9. Tighten screw plug in accordance with specifications.
  10. Position new gaskets, steel gasket and additional new gasket.
  11. Fit cover. Tighten bolts in accordance with specifications.

Tools required

  • Screw driver with socket Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Heat up screw plug 150° C

Source: Deutz service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.