- Clean outside of engine with diesel fuel or benzine.
- Drain engine oil in hot condition and fill in corrosion inhibitor oil.
- Pour oil out of air cleaner bowl, clean bowl and fill in inhibitor.
- Drain fuel from tank, mix well with 10% inhibitor and fill back into tank.
- Drain oil from injection pump and governor and refill with corrosion inhibitor oil.
- Run engine about 10 minutes so pipes, filter, pump and nozzles are filled with preservative mixture.
- Detach rocker chamber covers and lateral cover of injection pump; spray rocker chambers and spring chamber with mixture of diesel fuel and 10% anti-corrosive or injection pump testing oil; refit cover
- Turn engine over several times without firing to spray mixture into combustion chambers.
- Detach V-belts and spray pulley grooves with corrosion inhibitor; remove inhibitor before reusing engine.
- Tightly close openings of oil bath air cleaner intake and exhaust pipe.