- Check clearance with engine cold using a 0.15 mm (0.006 in.) feeler gauge.
- Turn crankshaft until piston of cylinder reaches compression dead center.
- Insert feeler gauge between rocker arm and valve; correct clearance is when gauge can be inserted with slight drag.
- If not, loosen lock nut of adjusting screw and adjust with screwdriver.
- Check that punch mark on oil nozzle points to rocker arm pad.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Valve clearance 0.15 mm (0.006 in.) cold