Home›Repair guides›Deutz›Checking Valve Clearance

Deutz — Checking Valve Clearance

Adjustments · valve train

From a Deutz owner's manual covering: F 3L 912, F 4L 912, F 5L 912, F 6L 912, F3L F4L F5L F6L. Check it applies to your exact model before use.

Browse Deutz generators & specs →

Procedure

  1. Check clearance with engine cold using a 0.15 mm (0.006 in.) feeler gauge.
  2. Turn crankshaft until piston of cylinder reaches compression dead center.
  3. Insert feeler gauge between rocker arm and valve; correct clearance is when gauge can be inserted with slight drag.
  4. If not, loosen lock nut of adjusting screw and adjust with screwdriver.
  5. Check that punch mark on oil nozzle points to rocker arm pad.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Valve clearance 0.15 mm (0.006 in.) cold

Source: Deutz owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.