Home›Repair guides›Deutz›Checking V-belt Tension

Deutz — Checking V-belt Tension

Adjustments

From a Deutz owner's manual covering: F 3L 912, F 4L 912, F 5L 912, F 6L 912, F3L F4L F5L F6L. Check it applies to your exact model before use.

Browse Deutz generators & specs →

Procedure

  1. Check by pressing with thumb that generator V-belt deflects inwards by max. 10-15 mm (0.4-0.6 in.).
  2. If re-tensioning needed, slacken hex. nut and securing bolts.
  3. Push generator outwards until correct belt tension is obtained.
  4. Securely retighten hex. nut and bolts.
  5. A new generator V-belt should be pulled up tight after short service, not later than 40 running hours.

Specs & values

Source: Deutz owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Deutz repair guides →