Detroit Diesel 149 — Control Valve Adjustment (on Bench) This procedure requires the use of two 0-40 psi (0 -
For the Detroit Diesel 149.
Browse Detroit Diesel generators & specs →
Before you start
- The control hose should be in place when
Procedure
- Attach one pressure gage to the discharge port of the
- Connect the second pressure gage between the
- Connect shop air pressure to the regulator valve.
- Loosen and back out the adjusting screw on the
- Adjust the air pressure regulator valve to obtain a
- Adjust the three-way valve screw until the gage on the
Source: manual:detroit-diesel-149-workshop-manual-sections-3-thru-7-ab.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.