Home›Repair guides›Detroit Diesel›Temporary Storage (30 Days or Less)

Detroit Diesel — Temporary Storage (30 Days or Less)

Maintenance · Engine

From a Detroit Diesel service manual — check it applies to your exact model before use.

Before you start

  • Wear adequate eye protection and do not exceed 40 psi (276 kPa) air pressure

Procedure

  1. Drain the engine crankcase.
  2. Fill the crankcase to the proper level with the recommended viscosity and grade of oil.
  3. Fill the fuel tank with the recommended grade of fuel; operate the engine for two minutes at 1,200 rpm and no load.
  4. Check the air cleaner and service it if necessary.
  5. If freezing weather is expected, add an ethylene glycol base antifreeze; drain the raw water system and leave drain cocks open.
  6. Clean the entire exterior of the engine (except the electrical system) with fuel oil and dry with compressed air.
  7. Seal all engine openings with waterproof, vaporproof material.

Specs & values

  • operate two minutes at 1,200 rpm and no load

Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.