Home›Repair guides›Detroit Diesel›Tapping Bottom Plug Bore

Detroit Diesel — Tapping Bottom Plug Bore

Repair & overhaul · Rear oil gallery bottom plug bore

From a Detroit Diesel service manual — check it applies to your exact model before use.

Before you start

  • EYE INJURY: To avoid injury from flying debris, wear a face shield or goggles.
  • Air pressure is used to keep as many chips as possible out of the oil galley; keep any sensitive areas covered.

Procedure

  1. Connect regulated and filtered air supply at 15 psi to the Air Fitting Adapter (J-47485-3).
  2. Using light force, start the tapping process. Ensure the tap is well lubricated at all times.
  3. Back the tap off every ¼ turn. The tap will bottom out on the tap stop.
  4. Turn off shop air and loosen the tap guide assembly set screw. Remove the Tap Guide Assembly (J-47485-6) from the Adaptor Block (J-47485-1).
  5. Check and clean the newly tapped hole.
  6. Check the front face of the tapped hole for burrs. If burrs are present, lightly stone the surface.
  7. Disconnect shop air from the Air Fitting Adaptor (J-47485-3).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Air supply: 15 psi
  • Back tap off every ¼ turn

Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.