Detroit Diesel — Shutoff Cable (Manual Shutoff) Adjustment
Adjustments
From a Detroit Diesel service manual — check it applies to your exact model before use.
Procedure
- Loosen the screw which secures the shutoff cable to the shutoff lever.
- Push the shutoff cable knob in the cab to fully seat it against the instrument panel.
- Place the shutoff lever in the Full Run-Fuel On Position.
- Move shutoff lever 1/16 in. to 1/8 in. away from Full Run-Fuel On Position. Secure cable to lever.
Specs & values
- 1/16 in. to 1/8 in.
Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.