Detroit Diesel — Restart Engine After Running Out of Fuel
Operation · Fuel system
From a Detroit Diesel operator's manual — check it applies to your exact model before use.
Procedure
- Fill fuel tank with recommended grade; if partial fill, add minimum 10 gallons (38 litres).
- Remove fuel strainer shell and element; fill shell with fuel oil; install.
- Remove and fill fuel filter shell and element with fuel oil.
- Start engine; check filter and strainer for leaks.
- If necessary, remove valve rocker cover and loosen a fuel pipe nut to bleed air; retighten securely.
Tools required
- Primer J 5956 Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Detroit Diesel operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.