Home›Repair guides›Detroit Diesel›Remove Air Shutdown Housing

Detroit Diesel — Remove Air Shutdown Housing

Repair & overhaul

From a Detroit Diesel service manual — check it applies to your exact model before use.

Before you start

  • Cover the blower opening to prevent dirt or foreign material from entering the blower.

Procedure

  1. Disconnect and remove the air ducts between the air cleaner and the air shutdown housing. On turbocharged engines, loosen hose clamps and slide hose back over air inlet tubes.
  2. Disconnect the shutdown mechanism from the air shutdown latch. Remove the crossover shaft between the two housings (12V and 16V) by removing cotter pins, loosening bolts and sliding couplings.
  3. Remove the eight bolts and washers attaching the air inlet housing to the air shutdown housing. Remove the air inlet housing and gasket.
  4. Remove the bolts, lock washers and washers attaching the air shutdown housing to the blower. Remove the housing, blower screen, striker plate and gasket. Cover the blower opening.

Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Detroit Diesel repair guides →