Detroit Diesel — Power Plant Assy. Installation
Installation · power plant assembly
From a Detroit Diesel service manual — check it applies to your exact model before use.
Applies to: Detroit Diesel Series 60 engine
Procedure
- Install the power plant assembly following the removal procedure in reverse order.
- Torque the power plant cradle mounting bolts to 113-144 lbf•ft (153-195 N•m).
- For automatic transmission with retarder, install transmission bracket tightened to 71-81 lbf•ft (96-110 N•m).
- Install the transmission's rubber damper assembly above transmission; respect damper tolerance of 58 mm.
- If fan drive was removed, reinstall and align it; refill cooling system; fill fuel filters with fuel oil if fuel system was drained; start engine and check for leaks and operation of controls and acce
Specs & values
- Cradle mounting bolts 113-144 lbf•ft (153-195 N•m)
- Transmission bracket 71-81 lbf•ft (96-110 N•m)
- Rubber damper tolerance 58 mm
Full service-parts list: Detroit Diesel Series 60 engine →
Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.