Home›Repair guides›Detroit Diesel›Installation of Fuel Doser Valve

Detroit Diesel — Installation of Fuel Doser Valve

Repair & overhaul · Fuel Doser Valve (FDV)

From a Detroit Diesel service manual — check it applies to your exact model before use.

Procedure

  1. With a new gasket, the shielding pot, and second new gasket in place, position the FDV and fasten with two Allen screws; torque each Allen screw to 20 Nm (15 lb ft) and then tighten a second time to 4
  2. Connect in and out coolant lines and torque to 33-35 Nm (24-26 lb ft).
  3. Connect dosing fuel line to injection nozzle and torque to 16-20 Nm (12-15 lb ft).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.