Home›Repair guides›Detroit Diesel›Adjust Load Limit (Hydraulic Governor)

Detroit Diesel — Adjust Load Limit (Hydraulic Governor)

Adjustments · Governor load limit screw

From a Detroit Diesel service manual — check it applies to your exact model before use.

Before you start

  • Do not overstress the linkage.

Procedure

  1. With governor cover off and load limit screw lock nut loosened, adjust screw to approximately 2 in from outside face of governor sub-cap boss to end of screw.
  2. Place and retain governor operating lever in the full-fuel position.
  3. Turn load limit adjusting screw until a .020 in space exists between fuel rod collar and terminal lever.
  4. If adjustment cannot be made with a feeler gage, turn the load limit adjusting screw in until injector racks just loosen on ball end of control levers.
  5. Release governor operating lever, hold adjusting screw, and tighten lock nut; install governor cover and tighten screws.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 2 in initial screw setting
  • .020 in space between fuel rod collar and terminal lever

Source: Detroit Diesel service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.