Home›Repair guides›Cummins/Onan›Winding Insulation Resistance Test

Cummins/Onan — Winding Insulation Resistance Test

Testing & diagnosis · generator

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKB, Kubota D1105 engine, Kubota V1305 engine, Kubota V1505 engine, Kubota V1903B engine, Kubota V2203B engine, Kubota V2803B engine, Kubota V3300-E2B engine

Procedure

  1. Apply 500 VAC megger between winding and ground for 10 minutes
  2. Record resistance at 1 minute and again at 10 minutes
  3. New generator with dry windings should read at least 5 megohms, polarization index at least 2
  4. In-service set should not read less than 1 megohm, polarization index not less than 2
  5. Dry windings and repeat test if low readings obtained

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 5 megohms minimum (new, dry)
  • 1 megohm minimum (in service)
  • polarization index >= 2

Full service-parts list: Cummins/Onan MDKB →, Kubota D1105 engine →, Kubota V1305 engine →, Kubota V1903B engine →, Kubota V3300-E2B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.