For the Cummins/Onan W3M-19, from the Cummins/Onan service manual.

Applies to: Cummins/Onan W3M-19, Cummins/Onan W2C engine

Procedure

  1. Remove all protective grease coatings and wipe unit clean.
  2. Inspect carefully for damage and correct it.
  3. Remove the plug from the exhaust outlet.
  4. Remove, clean and adjust spark plugs; crank engine several revolutions to distribute oil.
  5. Clean magneto distributor cap and breaker contacts; install new spark plug cables if needed.
  6. Examine fan belt, adjust or install new one as needed.
  7. Examine radiator hose, install new hose if needed.
  8. Check for leaks of gasoline, water and oil after filling; correct all leaks before starting.