Home›Repair guides›Cummins/Onan›Voltage Adjustment

Cummins/Onan — Voltage Adjustment

Adjustments · Generator output voltage

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKAV, Cummins/Onan MDKAW, Cummins/Onan MDKAZ, Cummins/Onan MDKB, Kubota D1105 engine, Kubota V1305 engine, Kubota V1505 engine, Kubota V1903B engine, Kubota V2203B engine, Kubota V2803B engine

Before you start

  • HAZARDOUS VOLTAGE! Touching uninsulated live parts inside the genset or connected equipment can result in severe personal injury or death.

Procedure

  1. Make proper fuel, exhaust, raw water and battery connections; ensure proper oil and coolant levels.
  2. Disconnect all generator loads and connect meters to measure AC volts and frequency.
  3. Start the genset and let voltage and frequency stabilize for 5 to 10 seconds.
  4. Rapidly press the control switch to START 6 times within 10 seconds.
  5. To raise voltage, press START and release quickly; each release raises voltage about 0.6 volt.
  6. To lower voltage, press START and release in about 2 seconds; each release lowers voltage about 0.6 volt.
  7. Normal operation resumes 20 seconds after the last adjustment.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Voltage change approximately 0.6 volt per press
  • Resume normal mode 20 seconds after last adjustment

Full service-parts list: Cummins/Onan MDKAV →, Cummins/Onan MDKAW →, Cummins/Onan MDKAZ →, Cummins/Onan MDKB →, Kubota D1105 engine →, Kubota V1305 engine →, Kubota V1903B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.