Cummins/Onan — Turbocharger Oil Priming Procedure
A Cummins/Onan service procedure — check it applies to your exact model before use.
Browse Cummins/Onan generators & specs →
Before you start
- Maintain proper oil level during priming
Procedure
- Disconnect wire from fuel solenoid valve
- Close throttle
- Crank engine while maintaining an external prime pressure of 15 psi (103 kPa) for 15 seconds
- Remove external priming equipment
- Replace plug in filter housing and torque to 15 to 20 ft-lb
- Reconnect wire to fuel shutoff valve
- Complete oil fill to H (high) mark on dipstick
Tools required
- Priming equipment capable of 15 psi pressure
- Socket wrench
Specs & torque values
- External prime pressure: 15 psi (103 kPa)
- Cranking duration: 15 seconds
- Filter plug torque: 15 to 20 ft-lb
Source: manual:904-0601 Onan DNB DNC DND DWB DWC DWD Series Genset Installation manual (01-1989).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.