Home›Repair guides›Cummins/Onan›Turbocharger Installation

Cummins/Onan — Turbocharger Installation

Installation · Turbocharger mounting

From a Cummins/Onan service manual covering: ST-50, T-18A, VT-50. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Check oil drain position; drain must be down or within 30 degrees of that position.
  2. Install gasket and position turbocharger on exhaust manifold flange; mount with capscrews.
  3. Put Teflon tape on inlet and drain fittings and install in bearing housing at specified torque.
  4. Install oil drain line from bottom of turbocharger to boss on engine block or oil pan.
  5. Add 2 to 3 oz [60 cc] of clean engine lubricating oil through the inlet opening.
  6. Fill the inlet line with clean lubricating oil and connect to turbocharger.
  7. Install hose connecting compressor air outlet to engine intake manifold connection.
  8. Install air cleaner and exhaust piping; check crankcase breather condition.

Specs & values

  • 2 to 3 oz [60 cc] clean engine lubricating oil through inlet
  • Oil drain within 30 degrees of down position

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.