Home›Repair guides›Cummins/Onan›Step 6 – Install standoffs

Cummins/Onan TUG MT8-37 — Step 6 – Install standoffs

Installation · Standoffs 132670 and 132672

For the Cummins/Onan TUG MT8-37, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. Thread 132670 into the front cover of the engine; tighten to 18 ft.lbs
  2. Thread 132672 into the water pump housing
  3. Tighten standoff 132672: Stage 1 to 89 in.lbs, then Stage 2 1/4 turn

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 132670: 18 ft.lbs
  • 132672 Stage 1: 89 in.lbs
  • 132672 Stage 2: 1/4 turn

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.