Home›Repair guides›Cummins/Onan›Troubleshoot − Engine Unstable (Hunts) (Genset)

Cummins/Onan — Troubleshoot − Engine Unstable (Hunts) (Genset)

Testing & diagnosis · Governor / fuel system

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan HDKA

Procedure

  1. Check fuel supply
  2. Check fuel lines for leakage
  3. Check loose wire connection
  4. Perform checks in step 01
  5. Check governor linkage for binding
  6. Check governor adjustments

Specs & values

  • SRT 00−041
  • Step 01 time 0.5 h
  • Step 02 time 0.8 h

Full service-parts list: Cummins/Onan HDKA →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.