Procedure
- Place the armature in a growler connected to alternating current.
- Hold a steel blade 1/4 inch from the armature laminations.
- Test all laminations from one side to the other.
- Revolve the armature about 1/8 revolution and test again.
- Continue until the armature has been tested completely around.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Steel blade held 1/4 inch from laminations