Home›Repair guides›Cummins/Onan›Testing the Armature for Short Circuits

Cummins/Onan — Testing the Armature for Short Circuits

Testing & diagnosis

From a Cummins/Onan owner's manual covering: 1.5UF-232S, 10.0UF-150S, 12.0UF-3S, 12.0UF-4S, 15.0UB-150S, 15.0UF-3S/104, 2.0UF-125S, 2.0UF-232S/32, 2.0UG-1S/135, 2.5UF-1S, 2.SUD-IS, 2.SUD-IS/ID…. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Place the armature in a growler connected to alternating current.
  2. Hold a steel blade 1/4 inch from the armature laminations.
  3. Test all laminations from one side to the other.
  4. Revolve the armature about 1/8 revolution and test again.
  5. Continue until the armature has been tested completely around.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Steel blade held 1/4 inch from laminations

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.