Home›Repair guides›Cummins/Onan›Testing Reference Transformer T21

Cummins/Onan — Testing Reference Transformer T21

Testing & diagnosis

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Leads are marked H1, H2, X1 and X2. H1-H2 are primary leads. X1-X2 are secondary leads.
  2. Measure resistance between H1-H2 and between X1-X2.
  3. Resistance between H1-H2 should be 133 to 139 ohms, and between X1-X2, 133 to 163 ohms at 77°F (25°C).
  4. Resistance between coils and from any terminal to transformer frame should be infinity.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 133 to 139 ohms at 77°F (25°C)
  • 133 to 163 ohms at 77°F (25°C)

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →