Cummins/Onan — Testing Output Bridge Diodes
Testing & diagnosis · Voltage regulator PC board
From a Cummins/Onan service manual covering: 12.0MDJC-3CR, 12.0MDJF-53CR, 15.0MDJF-18R, 15.0MDJF-3CR, 3.0MDJA, 3.0MDJA-3CR, 3omDJaiR, 4.0MCCK-3CR, 6.0MDJE-518R, 6.0MDJE-53CR, 6.5MCCK-3CR, 6.OMDJE-S18R…. Check it applies to your exact model before use.
Applies to: Cummins/Onan 12.0MDJF-53CR, Cummins/Onan 15.0MDJF-3CR, Cummins/Onan 3.0MDJA, Cummins/Onan 6.0MDJE-518R, Cummins/Onan 6.0MDJE-53CR, Cummins/Onan 6.5MCCK-3CR
Procedure
- Disconnect at least one lead of diode.
- Connect ohmmeter across diode, note reading.
- Reverse leads, note reading.
- Good diode has higher reading one direction than other.
- Replace defective diodes.
Tools required
- ohmmeter Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Full service-parts list: Cummins/Onan 12.0MDJF-53CR →, Cummins/Onan 15.0MDJF-3CR →, Cummins/Onan 3.0MDJA →, Cummins/Onan 6.0MDJE-518R →, Cummins/Onan 6.0MDJE-53CR →, Cummins/Onan 6.5MCCK-3CR →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.