Before you start

  • Do not coat generator brushes, commutator or collector rings with lubricant or preservative.

Procedure

  1. Drain crankcase completely and refill with M 4834 A Engine Preservative Oil (SAE 10); attach a warning tag.
  2. Run until completely out of gasoline, then restart and run on M 534 H unleaded undyed gasoline at least 10 minutes.
  3. While running, spray M 4834 A into the carburetor air intake for about two minutes.
  4. Open the throttle briefly, shut off ignition, and continue spraying until the engine stops.
  5. Drain the oil and gasoline; drain water at radiator bottom and rear of cylinder block.
  6. Remove each spark plug and pour two tablespoonfuls of rust inhibitor oil into each cylinder; crank the engine.
  7. Seal all openings in the engine and accessories with M 6471 non-hydroscopic adhesive tape.
  8. Spray all taped openings, accessories and exterior engine surfaces with M 4858 B Insulation Compound-Ignition.

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.