Home›Repair guides›Cummins/Onan›Storing the Generator Set (Out-of-Service Protection)

Cummins/Onan — Storing the Generator Set (Out-of-Service Protection)

Maintenance

From a Cummins/Onan operator's manual covering: P4500, P5000E, P5000e. Check it applies to your exact model before use.

Applies to: Cummins/Onan P4500, Cummins/Onan F7RTC engine

Before you start

  • Fuel additives can cause a risk of personal injury. Read and follow manufacturer's instructions.

Procedure

  1. Add a fuel preservative and stabilizer to the fuel tank, or let the generator set run out of fuel.
  2. Shut the fuel valve and drain the carburetor bowl (Figure 7).
  3. Remove the spark plug and squirt one tablespoon (about 30 cm3) of clean engine oil into the spark plug hole; turn engine over several revolutions; replace spark plug.
  4. Pull the recoil starter handle out slowly until compression is felt.
  5. Change engine oil and attach a tag indicating the viscosity of oil used.
  6. Disconnect the cables from the starting battery, negative (–) cable first, and store the battery per the manufacturer's recommendations.
  7. Store the generator set in a dry, protected area.

Specs & values

  • 1 tablespoon (about 30 cm3) clean engine oil

Full service-parts list: Cummins/Onan P4500 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.