Home›Repair guides›Cummins/Onan›Starting the Generator Set — Using the Recoil Starter

Cummins/Onan — Starting the Generator Set — Using the Recoil Starter

Operation

From a Cummins/Onan operator's manual covering: P4500, P5000E, P5000e. Check it applies to your exact model before use.

Applies to: Cummins/Onan P4500, Cummins/Onan F7RTC engine

Procedure

  1. Open the fuel valve (Figure 4).
  2. Pull the choke rod out to close the choke if the engine is cold (Figure 5).
  3. Check that the Start/On/Off switch is in the On position.
  4. With one hand on the generator, grip the recoil handle and pull it out smoothly and quickly. Repeat as necessary.
  5. Gradually push the choke rod in as the engine warms up.
  6. Let the engine warm up a few minutes before connecting tools or appliances.

Full service-parts list: Cummins/Onan P4500 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.