Cummins/Onan — Starting the Generator Set
Operation
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan HDZAA
Before you start
- Exhaust gas is deadly; never occupy the vehicle while the set is running without a working carbon monoxide detector.
Procedure
- Perform the pre-start checks.
- Press and release the Display ON button on the remote operator panel.
- Wait for GEN OFF to appear; if priming is needed wait at least one minute before pressing START.
- Press and hold the START button until the generator set starts; it will make up to three attempts.
- Press the GEN OFF button to reset the control if the set does not start after three attempts.
- Let the set warm up a few minutes until running smoothly before connecting loads.
- Check for fuel, oil and exhaust leaks and stop immediately if a leak is found.
Full service-parts list: Cummins/Onan HDZAA →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.