Home›Repair guides›Cummins/Onan›Starting (Cold Engine)

Cummins/Onan — Starting (Cold Engine)

Operation

From a Cummins/Onan operator's manual covering: 12.0MDJF-53CR, 12.0MDJF-53CR4, 12.0MDJF-54R, 12.0MDJF-55DR, 12.0MDJF-57R, 15.0MDJ F .. .4R 196 D, 15.0MDJF, 15.0MDJF-3CR, 15.0MDJF-3CR4, 15.0MDJF-5DR. Check it applies to your exact model before use.

Applies to: Cummins/Onan 12.0MDJF-53CR, Cummins/Onan MDJF (Onan J-series diesel) engine, Cummins/Onan MDJF engine

Before you start

  • Do not apply overvoltage to the starting circuit; overvoltage will destroy the glow plugs and air heater in two to three seconds.

Procedure

  1. Above 55 deg F, depress the manifold heater switch for one minute.
  2. Push START-STOP switch to its START position.
  3. Release switch after engine starts and reaches speed.
  4. Oil pressure should read at least 20 psi.

Specs & values

  • Oil pressure at least 20 psi

Full service-parts list: Cummins/Onan 12.0MDJF-53CR →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.