Before you start
- Do not apply overvoltage to the starting circuit; overvoltage will destroy the glow plugs and air heater in two to three seconds.
Procedure
- Above 55 deg F, depress the manifold heater switch for one minute.
- Push START-STOP switch to its START position.
- Release switch after engine starts and reaches speed.
- Oil pressure should read at least 20 psi.
Specs & values
- Oil pressure at least 20 psi
Full service-parts list: Cummins/Onan 12.0MDJF-53CR →