Home›Repair guides›Cummins/Onan›Starting and Stopping the Genset

Cummins/Onan — Starting and Stopping the Genset

Operation · Genset control panel

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKAV, Cummins/Onan MDKAW, Cummins/Onan MDKAZ, Cummins/Onan MDKB, Kubota D1105 engine, Kubota V1305 engine, Kubota V1505 engine, Kubota V1903B engine, Kubota V2203B engine, Kubota V2803B engine

Before you start

  • Exhaust gas is deadly; inspect exhaust system for leaks every startup and after every eight hours of operation

Procedure

  1. Make sure all CO detectors are working; check for swimmers.
  2. Turn off air conditioners and other large appliances.
  3. Push and hold control switch at START until genset starts.
  4. Amber lamp blinks rapidly; green lamp lights when up to speed.
  5. Let engine warm up two minutes before applying large loads.
  6. Check for water, coolant, fuel and exhaust leaks; stop if leak found.
  7. Monitor engine gauges if equipped.
  8. To stop: turn off loads, run two minutes, touch switch to STOP/PRIME.

Specs & values

  • Preheat can take up to 15 seconds; cranking stops in 20 to 60 seconds if it fails to start

Full service-parts list: Cummins/Onan MDKAV →, Cummins/Onan MDKAW →, Cummins/Onan MDKAZ →, Cummins/Onan MDKB →, Kubota D1105 engine →, Kubota V1305 engine →, Kubota V1903B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.