Cummins/Onan — Starting late 1991, many Parts Catalogs and Service
For these Cummins/Onan models: 10CCFO, 10CCO, 7CCFO, 7CCO.
Browse Cummins/Onan generators & specs →
Procedure
- 10-6 Specifications
- 1. Determine entry hole type: round, or slotted.
- 2. Determine exit hole type: fixed female thread (weld nut), round, or slotted.
- 3. Follow these SAE washer rules after determining exit hole type:
- a. Always use a washer between hardware and a slot.
- b. Always use a washer under a nut (see 2. above for exception).
- c. Use a washer under a bolt when the female thread is fixed (weld nut).
- 4. Refer to the diagram below, which depicts the preceding hardware configuration possibilities.
- 10-8 Specifications
- 2 ie pS /
- 0 oOo
- 8-32 in. lbs. (Nm) 20 (2.3) 25 (2.8) os 20 (2.3)
- 10-24 in. Ibs. (Nm) 32 (3.6) 40 (4.5) - 32 (3.6)
- 10-32 in. Ibs. (Nm) 32 (3.6) 40 (4.5) - -
- 10-10 Specifications ‘ TP-5595 5/93
- 14-459-1646 (North American Sales), 414-459-1614 (International)
- 1 INCH
Source: manual:TP5595 Kohler Gen Service 7CCO 10CCO Kubota (05-1993).PDF. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.