From a Cummins/Onan service manual covering: 0.6MAJ, 1.0MAJ, 1.5MAJ, 1.5MAJ-224R, 1.5MAJ-232R, 2.5MAJ. Check it applies to your exact model before use.

Applies to: Cummins/Onan 2.5MAJ

Procedure

  1. Remove solenoid from circuit.
  2. Apply 12 volts to terminal marked Battery.
  3. Jumper a ground wire to terminal marked S on start solenoid.
  4. Solenoid should activate.
  5. If solenoid is good, 12 volts can be read between S and ground.

Specs & values

  • 12 volts

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.