Home›Repair guides›Cummins/Onan›Servicing magneto breaker points, Power Unit PE-95-(1)

Cummins/Onan — Servicing magneto breaker points, Power Unit PE-95-(1)

Maintenance

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Remove the four screws holding the distributor cap and remove the cap; lift off the rotor.
  2. Insert two screwdrivers 180 degrees apart under the edge of the breaker cover and pry it off.
  3. Rotate engine crankshaft until breaker points are at widest separation.
  4. Loosen the fixed-contact screw and turn the eccentric screw until the correct gap is reached (0.015 inch).
  5. Tighten the locking screw after adjustment.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Breaker point gap 0.015 in.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.