Cummins/Onan — SCREW
For these Cummins/Onan models: PX12000e, RGV12 CSA_US_GU2001.
Applies to: Cummins Onan Px12000E, Cummins Onan Rgv12 Csa Us Gu2001
Procedure
- 15 to 5 mm (0.6" to 0.2") BRUSH BRUSH HOLDER
- 10. PREPARATION FOR STORAGE -31- The following procedures should be followed prior to storage of your generator for a period of 6 months or longer. ■Drain fuel from fuel tank and strainer (cup) carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult. ■In order to remove the fuel in the carburetor, run the engine at no-load until it stops. ■Disconnect the terminal of the battery. ■Change engine oil. ■Check for loose bolts and screws, tighten them if necessary. ■Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER TO CLEAN GENERATOR ! ■Store generator in a well ventilated, low humidity area. Screw for Drain
Source: manual:914-0111 Onan EGMBP Operators Manual (4-2008) .pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.