Home›Repair guides›Cummins/Onan›Storing the Generator Set

Cummins/Onan RV QD 3200 — Storing the Generator Set

Maintenance

For the Cummins/Onan RV QD 3200, from the Cummins/Onan service manual.

Applies to: Cummins/Onan HDZAA, Cummins/Onan RV QD 3200

Before you start

  • Store properly if idle for more than 120 days.

Procedure

  1. Change the engine oil and attach a tag indicating oil viscosity.
  2. Disconnect the battery cables (negative cable first) and store the battery per manufacturer recommendations.
  3. Plug the exhaust tail pipe to keep out dirt, moisture, bugs, etc.
  4. Close the fuel supply valve (if so equipped).

Full service-parts list: Cummins/Onan HDZAA →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →