Cummins/Onan RV QD 3200 — Starting the Generator Set
Operation · Operator panel
For the Cummins/Onan RV QD 3200, from the Cummins/Onan service manual.
Applies to: Cummins/Onan HDZAA, Cummins/Onan RV QD 3200
Before you start
- EXHAUST GAS is deadly.
Procedure
- Perform the pre-start checks.
- Press and release the Display ON button.
- Wait for “GEN OFF” to appear.
- Press and hold the START button until the generator set starts; up to three attempts.
- Press the GEN OFF button to reset the control if the generator set does not start after three attempts.
- Let the generator set warm up a few minutes before connecting loads.
- Check for fuel, oil and exhaust leaks.
Full service-parts list: Cummins/Onan HDZAA →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.