Before you start

  • Generator sets are heavy and can cause severe personal injury if dropped during removal. Use adequate lifting devices.

Procedure

  1. Disable the automatic generator set starting feature and disconnect the battery cables from the battery (negative first), then from the generator set.
  2. Disconnect the remote control wiring harness connector at the generator set.
  3. Disconnect the AC output leads at the generator set terminals.
  4. Disconnect the exhaust tailpipe from the muffler flange.
  5. Disconnect the supply and return fuel lines from the generator set.

Specs & values

  • Secure with four (4) Grade 5 bolts of at least 3/8 inch diameter

Full service-parts list: Cummins/Onan HDZAA →