Cummins/Onan RGA-IN1 — Flashing the Field

Repair & overhaul · Exciter field

For the Cummins/Onan RGA-IN1, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Before you start

  • Incorrect flashing procedure can damage the voltage regulator.

Procedure

  1. Assemble 12-volt storage battery, 10-amp fuse, momentary-on switch, and diode as shown.
  2. Connect positive lead to F1 (+) exciter stator lead.
  3. Connect negative lead to F2 (-) exciter lead.
  4. Start generator set and operate at normal speed.
  5. Close momentary-on switch just long enough for output voltage to build up, not longer than 5 seconds.
  6. Check output voltage, then shut down.
  7. Restart and operate at no load. Output voltage must build up without field flashing.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • max 5 seconds

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.