Home›Repair guides›Cummins/Onan›Battery Charging Check

Cummins/Onan RGA-IN1 — Battery Charging Check

Testing & diagnosis · Battery charging system

For the Cummins/Onan RGA-IN1, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. With engine running, check DC voltmeter. 12-volt system should read 13.5 to 15 volts.
  2. Check for loose drive belt, poor terminal connections, broken wires, bad regulator or alternator.
  3. If output voltage is over 15 volts, check for loose or corroded voltage regulator leads.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 13.5 to 15 volts

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.