From a Cummins/Onan owner's manual covering: 4UF-3N41, 4UF-3N42, 7UF-3N41, 7UF-3N42, 7UF-3N61. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • The gear drive generator rotation must not be reversed.

Procedure

  1. Remove only the scroll with screen attached.
  2. Turn it end for end and reinstall so the scroll will be at the opposite end of the air outlet hole.
  3. Run the generator and check for a strong flow of exhausted air for proper cooling.

Specs & values

  • Arrow on scroll must point in direction of rotation of generator shaft

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.