Home›Repair guides›Cummins/Onan›Restoring Residual Magnetism - Method K

Cummins/Onan — Restoring Residual Magnetism - Method K

Repair & overhaul · Exciter field

From a Cummins/Onan service manual covering: 02SX1N1A, 04SX1N, 04SX1N1A, 04SX1N1B, 04SX1N2B, 04SX1N3B, 04SX1N4B, 06SX1N, 06SX1N1A, 06SX1N1B, 06SX1N2B, 06SX1N3B…. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Connect a voltmeter across terminals E1 and E2.
  2. After starting set, touch positive lead of 6-volt dry cell lantern battery to F1 positive and negative lead to F2.
  3. When voltage starts to build up, remove battery leads.
  4. If voltage does not build up to normal and drops to zero when battery leads removed, trouble is faulty exciter component(s).
  5. May substitute 12-volt automotive battery if a 10-ohm resistance is connected in series to limit current.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →