Home›Repair guides›Cummins/Onan›Resistor Testing - Method G (Ohmmeter)

Cummins/Onan — Resistor Testing - Method G (Ohmmeter)

Testing & diagnosis

From a Cummins/Onan service manual covering: 02SX1N1A, 04SX1N, 04SX1N1A, 04SX1N1B, 04SX1N2B, 04SX1N3B, 04SX1N4B, 06SX1N, 06SX1N1A, 06SX1N1B, 06SX1N2B, 06SX1N3B…. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Measure resistance with an ohmmeter.
  2. See Table 3 for selecting resistance range (RX10, RX100, etc.) so readings are near center of meter scale.
  3. Isolate resistor by disconnecting one end before measuring resistance.
  4. Good if measured resistance falls within ±20 percent either way of Table 3 value.
  5. Defective if no continuity through resistor or measured resistance exceeds allowable tolerance.
  6. Stabilizing resistor can be adjusted to bring specified resistance within required limits.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • resistance within ±20 percent of Table 3 value

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.