Cummins/Onan — Resetting and Setting the Exerciser Clock Day and Time
Operation · Exerciser clock (Control Package B)
From a Cummins/Onan service manual covering: LT 100, LT 150, LT 200, LT 260, LT 30, LT 60. Check it applies to your exact model before use.
Applies to: Cummins/Onan TGHAA
Before you start
- Resetting the exerciser clock erases all existing day, time and exercise program settings.
Procedure
- Press all three buttons (arrow, plus, set) simultaneously to reset the time; display shows (– – : – –).
- Press the arrow button once to set the day-of-week; clock symbol flashes and display shows midnight (0:00).
- Press the plus button until the current day-of-week is displayed (1 = Monday, 2 = Tuesday, etc.).
- Press the arrow button again to set the hour (24-hour time); press plus until current hour shown.
- Press the arrow button again to set the minutes; press plus until current minutes shown.
- Press the arrow button eight times to return to normal operating mode.
Full service-parts list: Cummins/Onan TGHAA →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.