Cummins/Onan — Reset the Exerciser/Change-over Clock
Operation
From a Cummins/Onan service manual — check it applies to your exact model before use.
Browse Cummins/Onan generators & specs →
Before you start
- Resetting the clock erases all existing day, time and program settings.
Procedure
- Depress and hold the (-) (+), (Menu) and (OK) buttons simultaneously.
- When all aspects of the LCD display appear, release the buttons.
- RESET appears, then the display returns to default date 1/1/2004 and time 0:00.