Cummins/Onan — Replacing Transfer Switch Coil (60 Through 100 Ampere)
Repair & overhaul
From a Cummins/Onan service manual — check it applies to your exact model before use.
Browse Cummins/Onan generators & specs →
Procedure
- Disconnect the coil lead wires.
- Pull off the hairpin-shaped retaining clips holding the control rod and slide out the control rod (use needle-nose pliers).
- Slide out the stationary armature and coil assembly.
- Remove the defective coil from the stationary armature and replace with new coil.
Tools required
- needle-nose pliers Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.